Description Component series 2X Analog, Euro-card format For valves: 4WRPH 6…L-2X Features Double card for simultaneous operation of two high-response valves Controlled output stage Enable input Short-circuit-proof outputs Adjustable zero point Cable break detection for actual value cable Product description Applications 2-axis control in presses, forming machines and machine tools. Plug-in connections 2 x DIN 41612, 32-pole, for low-power signals (command value, enable, etc.). Screw-plug-in connection to the valve and for supply voltage on handle side (ST 4, 5 and ST 9, 10) included in the scope of delivery. Test points IC base on handle side for control measurements and signal inputs. Displays For cable break, enable and undervoltage. Direct voltage controller (DC/DC converter) For the supply of command value encoders, position transducers and internal supply together for both channels. Type code 01 Valve amplifiers for control valves, analog, Euro-card format VT-KRRA2 02 For valves: 4WRPH 6…L-2X 527 03 Component series 20 ... 29 (20 ... 29: unchanged technical data and pin assignment) 2X 04 Version: standard V0 05 2-channel variant 2CH 01 02 03 04 05 VT-KRRA2 ‒ 527 ‒ 2X / V0 / 2CH Technical data General Component series 2X Material number Data sheet 1819929052 Type of electronics Analog Design Double euro-card Voltage supply Operating voltage Nominal U V 24 Lower limit value UB(t)min V 21 Upper limit value UB(t)max V 40 Ripple 1) % Power consumption P VA 37 Current consumption max. Imax A 1.5 1) In case of ripple > 10 %, an upstream smoothing capacitor is required (recommendation: capacitor module VT 11110) Analog inputs Command value source External electronic control system, internal reference voltage Command value Voltage Differential input U V 0 ... ±10 Input resistance R kΩ ≥ 100 position value 1) Voltage U V 0 … ±10 1) RL > 10 kΩ Digital inputs Enable 1) On (active) U V 8.5 ... 40 1) RE = 100 kΩ Digital outputs Cable break error message No error 1) UB V 24 Error UB V 0 1) Imax = 100 mA Solenoid outputs Solenoid current max. Imax A 2.9 Position transducer Position transducer supply 1) U V ±15 1) Imax = 200 mA, short-circuit-proof Adjustment options Zero point calibration setting range % ± 5 Displays LED display Green 1 Enable Yellow 1 Cable break actual value Red UB too low Other information Reference voltage Potentiometer supply U V ±10 (Imax = 10 mA) Anschlussart Connector DIN 41612, design D, as well screw-plug-in connection on handle side Ambient temperature range ϑ °C 0 … 70 Storage temperature range ϑ °C -20 … 70 Weight m kg 0.54 (For applications outside these values, please consult us!) Symbols/Circuit diagrams Dimensions Dimensions in mm Dimensions in mm Project planning information The amplifier card may only be unplugged and plugged when de-energized. The distance to aerial lines, radios, and radar systems has to be at least 1 m. Do not lay solenoid and signal lines near power cables. For signal lines and solenoid conducto
Бесплатная доставка по РФ при заказе от 50 000 р.
Компания ООО «Индатэк» работает с юридическими лицами по всей территории России. Каждый день мы осуществляем доставку заказов от Калининграда до Владивостока. Вместе с отгруженным товаром, клиент получает бухгалтерские и гарантийные документы на 12 месяцев. По желанию, вы можете продлить срок гарантии.