Горячая линия: 8(800)333-08-79
Валюта

Артикул: rx7099
Бренд: Bosch Rexroth

Усилители для высокодинамичных клапанов VT-VRPA2-537-1X/V0/RTP

Уточните у менеджера

  • Описание товара
  • Оплата и доставка
Description Component series 1X Analog, Euro-card format For valves: 4WRP 10 Features Controlled output stage Closed-loop position control with PID characteristics Fast energization and fast deletion for short actuating times Enable input Short-circuit-proof outputs Adjustable ramp time, sensitivity and zero point Cable break detection for actual value cable Type code 01 Valve amplifier for high-response valves with two solenoids, analog, euro-card format VT-VRPA2 02 For valves: 4WRP 10 537 03 Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions) 1X 04 Version: standard V0 05 Adjustable ramp that can be switched off RTP 01 Valve amplifier for high-response valves with two solenoids, analog, euro-card format VT-VRPA2 02 For valves: 4WRP 10 537 03 Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions) 1X 04 Version: standard V0 05 Adjustable ramp that can be switched off RTP Technical data General Component series 1X Material number Data sheet 1819929075 Type of electronics Analog Design Euro-card Voltage supply Operating voltage Nominal U V 24 Lower limit value UB(t)min V 21 Upper limit value UB(t)max V 40 Ripple 1) % Power consumption P VA 60 Current consumption max. Imax A 2.5 1) In case of ripple > 10 %, an upstream smoothing capacitor is required (recommendation: capacitor module VT 11110) Analog inputs Command value source Potentiometer 10 kΩ supplied with 10 V internal reference voltage, external signal source Command value Voltage Differential input U V ​0 ... ±10 Input resistance R kΩ ≥ 100 grounded on one side, first input Ucommand V ​0 … ±10 grounded on one side, second input Ucommand V ​0 … ±10 Actual value valve Voltage U V 10.2 (7.8 kHz) Digital inputs Enable 1) On (active) U V 8.5 ... 40 Ramp switch-off U V 8.5 ... 40 1) RE = 100 kΩ Analog outputs Test point 1) Actual value U V 0 ... ±10 1) Values for potentiometers in end position (cw) and for "zero potentiometer" in central position Digital outputs Cable break error message No error 1) UB V 24 Error UB V 0 Ramp timeout 1) UB 24 V no timeout UB 0 V 1) Imax = 100 mA Solenoid outputs Solenoid current max. Imax A 3.7 Solenoid output Other properties Clocked current controller Cable length for 1.5 mm2 L m 20 for 2.5 mm2 L m 50 Position transducer Cable length Position transducer L 50 m at 100 pF/m Adjustment options Zero point calibration setting range % ± 10 Zero point calibration information Set at Ue = ±0,3 ... ±0,5 V Range sensitivity adjustment % 50 ... 100 Displays LED display Green 1 Enable Yellow 1 Cable break actual value Yellow 2 Ramp off Red UB too low Other information Reference voltage Potentiometer supply U V ±10 (Imax = 50 mA) Special features Short-circuit-proof output, cable break detection for actual value line, position control with PID behavior, pulsed output stage, fast energization and fast deletion for short actuating times, ramps with quadrant recognition, compensation of the dead zone in centra

Бесплатная доставка по РФ при заказе от 50 000 р.

Компания ООО «Индатэк» работает с юридическими лицами по всей территории России. Каждый день мы осуществляем доставку заказов от Калининграда до Владивостока. Вместе с отгруженным товаром, клиент получает бухгалтерские и гарантийные документы на 12 месяцев. По желанию, вы можете продлить срок гарантии.

Бесплатная доставка

При заказе от 50000 руб.

Только с юридическими лицами

Цены указаны с НДС

Гарантийный сервис

И постгарантийное обслуживание