Description Product description Structural design and attachments Structural design 1 Threaded bolt (galvanized steel) 2 Lock nut (galvanized steel) 3 Piston rod (stainless steel) 4 Thread (for mounting fastening elements) 5 Cover (aluminum, anodized) 6 Housing (aluminum, anodized) 7 Screw journal 8 Base (aluminum, anodized) 9 Lube connection (on two sides) 10 Cover for T-slot for switches 11 Service openings Attachments 12 Motor 13 Gear (optional) 14 Flange (aluminum, anodized) 15 Belt side drive (aluminum, anodized) Motor flange and coupling The motor flange is used to fasten the motor to the EMC and as a closed housing unit for the coupling. With the coupling, the drive torque of the motor is transmitted free of distortive stresses on the screw journal of the EMC. Belt side drive This configuration results in the shortest overall length of the EMC possible. The space-saving, closed housing serves as protection for the belt, motor bracket and to connect fastening elements. Gear ratio i = 1 : 1.5 Mounting examples Technical data Note on dynamic load rating In relation to the desired service life, an equivalent dynamic axial load of up to about 20 % of the dynamic load rating (C) has generally proven effective. Do not exceed the technical data. Load capacities and moments Size EMC-160-HP Drive PLSA d0 x P mm 48 x 5 48 x 10 C N 179000 Fmax N 95000 100000 General technical data Size EMC-160-HP Drive PLSA d0 x P mm 48 x 5 48 x 10 Lad without trunnion mm 418.5 Lad with trunnion mm 482 smin mm 130 smax perm mm 1500 mca fix kg 10.7 mca var kg/mm 0.0115 kg fix kg 28.6 kg var kg/mm 0.035 Drive data Size EMC-160-HP Drive PLSA d0 x P mm 48 x 5 48 x 10 Fmax N 95000 100000 Mp Nm 93.5 198.9 vmax m/s 0.26 0.52 mca fix kg 10.7 mca var kg/mm 0.0115 kJ fix kg·mm² 5598 5618 kJ var kg·mm 4.095 4.091 kJ m mm² 0.633 2.533 MRs Nm 8 amax m/s² 30 np rpm 3125 η 0.8 Mass of the EMC-HP Weight calculation without motor and without motor attachment*) Moved mass of system*) *) When calculating the mass of the entire system, the masses of the attachments/fastening elements must also be taken into account. The indicated values apply in case of compliance with the specified relubrication intervals and to standard operation. For short stroke operation (stroke (see "Normal operating conditions" table and "Stroke definition" section). For more calculations see configurators, and tools can be found here Load on the piston rod Horizontal installation Vertical mounting Loading the piston rod with transverse forces is not permissible Normal operating conditions Size EMC-160-HP Drive PLSA d0 x P mm 48 x 5 48 x 10 Permissible ambient temperature, cylinder with Rexroth servo motor 1) 0 °C ... 40 °C Permissible ambient temperature for cylinder mechanics 2) -10 °C ... +50 °C Permissible ambient temperature for cylinder mechanics with PLSA and low-temperature grease 3) -30°C ... +50°C Duty cycle 4) % 100 Protection type IP 54; housing IP 65 Normal stroke The distance traveled per cycle is
Бесплатная доставка по РФ при заказе от 50 000 р.
Компания ООО «Индатэк» работает с юридическими лицами по всей территории России. Каждый день мы осуществляем доставку заказов от Калининграда до Владивостока. Вместе с отгруженным товаром, клиент получает бухгалтерские и гарантийные документы на 12 месяцев. По желанию, вы можете продлить срок гарантии.