Description Lightweight precision tandem housing (aluminum) Two eLINE Linear Bushings Integrated wiper seals Reduced radial clearance Initial lubrication with Dynalub 510 Technical data General technical data Ø d mm 12 16 20 25 30 40 amax m/s² 150 vmax m/s 5 m kg 0.17 0.24 0.31 0.57 0.8 1.54 FR 1) N 0.8 1 1.5 2 2.5 3 Breakaway force N 1.5 2 3 4.5 6 8 Shaft radial clearance h6 µm + 8 - 24 + 9 - 25 + 12 - 24 + 18 - 25 Operating conditions Permissible ambient temperature (min ... max) -10 °C ... +80 °C 1) Frictional drags generated by Linear Bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication. Load capacities and load moments Ød mm 12 16 20 25 30 40 C 1) N 1310 1700 2290 4760 6250 10360 C0 1) N 980 1140 1800 3900 5580 9300 ML0 Nm 13 18 21 59 103 204 1) The load ratings apply for the main direction of loading. If the load direction is not the main direction of loading, the load ratings must be multiplied by the following factors: Ø d 12 and 16: f = 0,90, f0 = 0.86, Ø d 20 to 50: f = 0.79, f0 = 0.68 The load ratings are based on a total travel of 100, 00 m. When based on 50 000 m, the values in the table need to be multiplied by 1.26. Legend Symbol Description Unit Ød Shaft diameters mm amax Maximum acceleration travel m/s2 C Dynamic load capacity N C0 Static load capacity N FR Friction force N m Mass kg ML0 Static longitudinal moment load capacity Nm vmax Maximum permissible speed m/s2 Effect of load direction on load rating The listed load ratings should be chosen depending on installation in minimum or maximum position and should be based on the calculations. If the load direction is clearly defined and the Linear Bushings can be installed in maximum position, the load ratings Cmax. (dynamic load rating) and C0 max (static load rating) can be used. If aligned installation is not possible or the load direction is not defined, the minimum load ratings must be used. Reduced load capacity with short stroke In case of short stroke, the service life of the shafts is less than that of Linear Bushings. The load ratings C specified in the tables must therefore be multiplied by the factor f.s . 1) fs = factor 2) s = stroke Definition of dynamic load ratings Dimensions Dimensions Ød mm 12 16 20 25 30 40 D mm 19 24 28 35 40 52 A mm 40 45 53 62 67 87 E1 29 mm ±0.15 34 mm ±0.15 40 mm ±0.15 48 mm ±0.15 53 mm ±0.15 69 mm ±0.15 E2 35 mm ±0.15 40 mm ±0.15 45 mm ±0.15 55 mm ±0.15 70 mm ±0.15 85 mm ±0.15 H mm 17 19 23 27 30 39 Tolerance for H 1) µm + 24 0 + 25 0 + 26 0 H1 mm 33 38 45 54 60 76 H4 mm 11 13 15 17 19 24 L mm 60 65 85 105 125 N1 mm 16 18 22 26 29 38 N2 mm 11 13 18 22 S 2) mm 4.3 5.3 6.6 8.4 S1 M5 M6 M8 M10 1) In relation to Ø d. 2) Fixing screws ISO 4762-8.8 Legend Symbol Description Unit Ød Shaft diameters mm C/C0 Main direction of loading ML0 Static torsional moment laod capacity Nm Project planning information Life expectancy calculation Mounting General mounting instructions
Бесплатная доставка по РФ при заказе от 50 000 р.
Компания ООО «Индатэк» работает с юридическими лицами по всей территории России. Каждый день мы осуществляем доставку заказов от Калининграда до Владивостока. Вместе с отгруженным товаром, клиент получает бухгалтерские и гарантийные документы на 12 месяцев. По желанию, вы можете продлить срок гарантии.